1769-IF4; 1769-IF4I; 1769-IF8; 1769-IG16; 1769-IM12; 1769-IQ16; 1769-IQ16F. Allen Bradley CompactLogix. Bulletin 1769 Compact I/O. MicroLogix 1500 Programmable Controllers User Manual: 1764-UM001: EN: More 1769 Compact I/O. CrossWorks — Convert competitive catalog numbers to similar Allen-Bradley. User Manual Compact I/O Analog Modules (Cat. 1769-IF-OF2) Allen-Bradley. Introduction: Environmentals. 1769 Compact Analog I/O Modules. Inputs/Outputs Signal Range Resolution Backplane current Power supply distance rating 1769-IF4 4 inputs, differential or single -ended.
Micro. Logix. The Micro. Logix range covers quite a few models now, from the tiny Micro. Logix 1. 00. 0 to the latest Micro.
Logix 1. 40. 0 featuring online programming and ethernet communication for programming and messaging. Watch for these limitations of products in the range which catch people out: Only newer models such as Micro. Logix 1. 10. 0 and 1. For this reason alone, we recommend against buying any of the legacy Micro. Logix controllers. Each controller suits only one type of expansion IO - refer to table below for compatibility. The model family number - 1.
The latest models are the Micro. Logix 1. 10. 0 and Micro. Logix. 14. 00, which are far superior to the much older Micro. Logix 1. 50. 0 for example. The Micro. Logix 1. CPU. The serial port on most Micro. Logix controllers is a mini- DIN plug.
CompactLogix 5370 L3 programmable automation controllers (PAC) are designed to meet the growing need for a higher performance controller. 1769-IF4; 1769-IF4I; 1769-IF8; 1769-IG16; 1769-IM12; 1769-IQ16; 1769-IQ16F; 1769-IQ32; 1769-IQ32T; 1769-IQ6OW4; 1769-IQ6XOW4. Manufacturer Allen Bradley PanelView.
The Micro. Logix 1. LSP CPU provides a second serial port, but this is a 9 pin D- connector allowing use of a standard cross- over cable for programming. The standard programming cable is a part- number 1. CBL- PM0. 2, with a DIN plug one end and 9 pin D- Connector the other. For connecting to an HMI, the double DIN plug 1. CBL- HM0. 2 cable is used. The Micro. Logix family has no chassis - the 'backplane' for data is conducted through each expansion module.
Compact I/O Analog Modules 1769-IF4, -IF8, -OF2, -OF8C, and. CompactLogix User Manual 1769-UM007. Rockwell Automation Rockwell Automation. Allen Bradley 1769-If4 1769If4 I/O Module $355.89. Allen Bradley 1746-Fio4I 1746Fio4I I/O Module Allen Bradley 1746-Og16 Ser.C I/O Module 5.0. Allen Bradley 1769-IQ16 Input Module, 16-Points (8 Points/Group), Voltage. Allen-Bradley publication 1770-4.1, for. 1769-IF4I - Galco can perform PLC - I/O Module Repairs for most industrial applications. On-Site Service is available for your Allen Bradley* 1769-IF4I. Call 800-575-5562 to schedule On-Site.
Note the (Micro. Logix 1. IO also requires this backplane to be terminated with 'End Covers'The 1. IO family has strict rules concerning the number of modules each power supply can accommodate. The rules are based on the maximum number of modules between the power supply and the module in question.
Many functions that were built into the PLC and SLC families become optional modules in the Micro. Logix family - Real- time clock, backup memory for example.
Beware of the various power supply and IO voltage versions. There are various permutations of AC and DC, & extra low and low voltage, ordering details for Micro. Logix 1. 10. 0 and Micro. Logix 1. 40. 0 are available on separate pages.
Micro. Logix Family. Model Number. Base IOIO Capability. IO Expansion. Family.
Relative Ranking. Ethernet Prg/MSG1. Online Programming. Recommended. 2Micro. Logix 1. 00. 01. 76. Points. 17. 61. 5Via Net- ENINo. No. Micro. Logix 1.
Modules / 1. 44 Points. Yes. Yes. Yes. Micro. Logix 1. 20. 01. 76. Modules / 1. 36 Points. Via Net- ENINo. No.
Micro. Logix 1. 40. Modules / 2. 56 Points. Yes. Yes. Yes Micro.
Logix 1. 50. 01. 76. Modules / 5. 12 Points. Via Net- ENINo. No. Ethernet network programming, messaging and HMI data connection is available, but distributed IO (such as Point. IO for example) is not. Recommendation based on project requirements independent of existing or legacy equipment.
Is there any information missing here? Send a suggestion to This email address is being protected from spambots. You need Java. Script enabled to view it. We promise NOT to correspond with you in any form unless you request.
Note that we don't typically provide technical advice by email.